Prepare for the review
- Current product TDS and Part A and Part B SDS
- Graduated measuring containers or a suitable scale for the specified method
- A batch record for temperature, quantity and observations
Read the ratio and its measurement basis
Identify the exact resin and hardener before measuring. A ratio must say whether it is by volume or by weight. The supplied OS-820AB technical information specifies 1:1 by volume. Its two components do not become interchangeable with any other resin simply because another kit also says 1:1. Follow the instructions for the quoted formulation rather than a generic mixing chart.
Do not convert the ratio by guessing
Equal volumes can have different masses. If you want to use a scale for a system specified by volume, request the manufacturer’s approved weight ratio. Do not substitute equal weights, add extra hardener to accelerate curing, or estimate the ratio from the bottle shape. For a 2:1 by-volume system, two equal volume units of resin require one of hardener; that example does not establish its weight ratio.
Distinguish working time from cure time
Working time describes the usable handling window of the mixed resin under stated conditions. It is not the point at which the casting is ready to demold or package. OS-820AB lists about 35 minutes of usable time at 25°C for a 50 g mix and a separate 24-hour room-temperature cure reference. Batch mass, environment and geometry matter when translating test figures into a workshop process.
Make a batch record you can repeat
Record the product and lot references, measurement method, quantities of A and B, room temperature, substrate, mixing procedure and start time. Follow the prescribed mixing method, including the container walls and base. Note when application becomes difficult and when the piece meets the instructed handling criteria. Keep an approved sample with the record, rather than relying on memory.
Choose the resin around the application
A coating kit and a deep-pour kit should not share an assumed depth limit. For artwork and decorative surfaces, review the 1 gal coating kit. For a river-table cavity, measure the void and discuss the 3 gal deep-pour formulation separately. Send those measurements, pack requirements and estimated sets in your inquiry. Obtain current processing and safety instructions before production.
TAKE THIS WITH YOU
Measure using the basis specified for the exact resin, then approve the process on a representative sample.
Use the current instructions and safety documentation for your exact product. Technical figures quoted here refer to the named supplied TDS and its test conditions; they do not establish suitability for every project.